Check valves are mandatory armatures for eliminating back-reverse flow of media like steam, saturated steam, liquids, gas (non acidic and non caustic medias) on mains.
| SPARE PARTS | ||
| No | Description | Material |
| 1 | BODY |
GJS-400-18-LT/395 |
| 2 | COVER | ST37 |
| 3 | SPRING | STAINLESS SPRING STEEL / SS 420 |
| 4 | BOLT | 35 |
| 5 | FLAP | STAINLESS STEEL / C.S+13Cr |
| 6 | SEAT | STAINLESS STEEL / SS304~ SS420 |
| 7 | GASKET | GRAPHITE + STAINLESS STEEL / +SS304 |
| DIMENSIONS | |||||||||||||||||
| Size | PN16 | PN25 | PN40 | ||||||||||||||
| L | d | d1 | N-Ø | H | L | d | d1 | N-Ø | H | L | d | d1 | N-Ø | H | |||
| DN15 | 130 | 95 | 65 | 4*14 | 70 | 130 | 95 | 65 | 4*14 | 70 | 130 | 95 | 65 | 4*14 | 70 | ||
| DN20 | 150 | 105 | 75 | 4*14 | 70 | 150 | 105 | 75 | 4*14 | 70 | 150 | 105 | 75 | 4*14 | 70 | ||
| DN25 | 160 | 115 | 85 | 4*14 | 80 | 160 | 115 | 85 | 4*14 | 80 | 160 | 115 | 85 | 4*14 | 80 | ||
| DN32 | 180 | 140 | 100 | 4*18 | 80 | 180 | 140 | 100 | 4*18 | 80 | 180 | 140 | 100 | 4*18 | 80 | ||
| DN40 | 200 | 150 | 110 | 4*18 | 85 | 200 | 150 | 110 | 4*18 | 85 | 200 | 150 | 110 | 4*18 | 85 | ||
| DN50 | 230 | 165 | 125 | 4*18 | 95 | 230 | 165 | 125 | 4*18 | 95 | 230 | 165 | 125 | 4*18 | 95 | ||
| DN65 | 290 | 185 | 145 | 4*18 | 110 | 290 | 185 | 145 | 8*18 | 110 | 290 | 185 | 145 | 8*18 | 110 | ||
| DN80 | 310 | 200 | 160 | 8*18 | 130 | 310 | 200 | 160 | 8*18 | 130 | 310 | 200 | 160 | 8*18 | 130 | ||
| DN100 | 350 | 220 | 180 | 8*18 | 155 | 350 | 235 | 190 | 8*22 | 155 | 350 | 235 | 190 | 8*22 | 155 | ||
| DN125 | 400 | 250 | 210 | 8*18 | 165 | 400 | 270 | 220 | 8*26 | 165 | 400 | 270 | 220 | 8*26 | 165 | ||
| DN150 | 480 | 285 | 240 | 8*18 | 215 | 480 | 300 | 250 | 8*26 | 215 | 480 | 300 | 250 | 8*26 | 215 | ||
| DN200 | 600 | 340 | 295 | 12*22 | 285 | 600 | 360 | 310 | 12*26 | 285 | 600 | 375 | 320 | 12*30 | 285 | ||
| DN250 | 730 | 405 | 355 | 12*28 | 325 | 730 | 425 | 370 | 12*30 | 325 | 730 | 450 | 385 | 12*33 | 325 | ||
| DN300 | 850 | 460 | 410 | 12*28 | 365 | 850 | 485 | 430 | 16*30 | 365 | 850 | 515 | 450 | 16*33 | 365 | ||
| CONNECTION | FLANGED | |||||||||||||
| SIZES | DN15 | DN20 | DN25 | DN32 | DN40 | DN50 | DN65 | DN80 | DN100 | DN125 | DN150 | DN200 | DN250 | DN300 |
| WEIGHTS (KGS) | 2,2 | 2,97 | 3,84 | 6,51 | 7,7 | 11,25 | 17,38 | 23,25 | 31,45 | 48,41 | 62,93 | 103 | ||
| OPERATING CONDITIONS | |
| MAX. OPERATING PRESSURE PMA (BAR) | 16 |
| MAX. ALLOWABLE PRESSURE PMA (BAR) | 24 |
| MAX. ALLOWABLE TEMPERATURE TMA (ºC) | -20~+200 |