Referans conditions |
Flow conditions similar to EN29104 |
Medium :Water,gaz,steam | |
Electrical conductivity: ≥ 300 μS/cm | |
Temperature: +10...+30°C / +50...+86°F | |
Inlet part: ≥ 10 DN | |
Operating pressure: 1 bar / 14.5 bar | |
Correctness of flow meter | For liquid: % 1.0 Gas and steam : % 1.5 |
PROCESS CONTROL | |
Process temperature |
T1 Level: -20...+70°C |
T2 Level: -20...+250°C | |
T3 Level: -20...+350°C | |
Ambient Temperature (all versions) | STANDARD (Aluminium body) |
-10…+55°C | |
Storage Temperature | -20...+70° |
PRESSURE | |
EN 1092-1 |
DN200…DN300: PN10 |
DN100…DN200: PN 16 | |
DN15…DN80: PN 25 |
Nominal DIA | Liquid | Gas | Steam | |
(mm) | inç | Flow (m3/h) | Flow(m3/h) | Flow(m3/h) |
15 | 1/2" | 1.2 to 6.2 | 5 to 25 | 5-25 |
20 | 3/4" | 1.5 to 10 | 8 to 50 | 8-50 |
25 | 1" | 1.6 to 16 | 10 to 70 | 10-70 |
32 | 11/4" | 1.5 to 15 | 14 to 100 | 15-150 |
40 | 11/2" | 2.5 to 25 | 22 to 220 | 22-220 |
50 | 2" | 3.5 to 35 | 36 to 320 | 36-320 |
65 | 21/2" | 6.5 to 65 | 50 to 480 | 50-480 |
80 | 3" | 10 to 100 | 70 to 640 | 70-640 |
100 | 4" | 15 to 150 | 130 to 1100 | 130-1100 |
125 | 5" | 25 to 250 | 200 to 1700 | 200-1700 |
150 | 6" | 36 to 380 | 280 to 2240 | 280-2240 |
200 | 8" | 62 to 650 | 580 to 4960 | 580-4960 |
250 | 10" | 140 to 1400 | 970 to 8000 | 970-8000 |
300 | 12" | 200 to 2000 | 1380 to 11000 | 1380-11000 |
Dia:D (mm) | Pipe Specification | H | L | L1 | d | d1 |
15 | Φ19×1.5 | 290 | 180 | 80 | 68 | 135 |
20 | Φ26×3 | 290 | 180 | 80 | 68 | 135 |
25 | Φ32×3.5 | 290 | 180 | 80 | 68 | 135 |
32 | Φ39×3.5 | 290 | 180 | 80 | 68 | 135 |
40 | Φ49×4.5 | 295 | 180 | 80 | 80 | 140 |
50 | Φ59×4.5 | 300 | 180 | 80 | 88 | 145 |
65 | Φ74×4.5 | 308 | 200 | 80 | 105 | 165 |
80 | Φ89×4.5 | 315 | 200 | 80 | 120 | 180 |
100 | Φ109×4.5 | 328 | 200 | 80 | 148 | 210 |
125 | Φ133×4.5 | 340 | 220 | 85 | 174 | 235 |
150 | Φ159×4.5 | 351 | 220 | 90 | 196 | 270 |
200 | Φ219×9 | 378 | 220 | 105 | 250 | 325 |
250 | Φ273×11 | 402 | 250 | 120 | 300 | 375 |
300 | Φ325×12 | 428 | 300 | 135 | 350 | 425 |