OPERATING CONDITIONS | ||
PROCESS TEMPERATURE | HARD RUBBER LINER : -5..+60°C | |
POLIPROPILEN GASKET | ||
PTFE CONTA | ||
AMBIENT TEMPERATURE | STANDARD (WITH ALUMINUM CONVERTER HOUSING) | |
(ELECTRONICS |
||
-20…+70°C |
INSTALLATION CONDITIONS | |
INSTALLATION | TAKE CARE THAT FLOW SENSOR IS ALWAYS FULLY FILLED. |
FOR DETAILED INFORMATION SEE CHAPER ″CAUTIONS FOR |
|
FLOW DIRECTION | FORWARD ON FLOW SENSOR INDICATES POSITIVE FLOW DIRECTION. |
ARROW ON FLOW SENSOR INDICATES POSITIVE FLOW DIRECTION. | |
INLET RUN | ≥ 5 DN |
OUTLET RUN | ≤ 2 DN |
SIZE PN16 |
L | d | d1 | d2 | H | N-Ø |
DN10 | 160 | 90 | 60 | 41 | 360 | |
DN15 | 160 | 95 | 65 | 45 | 360 | 4-14 |
DN20 | 165 | 105 | 75 | 58 | 360 | 4-14 |
DN25 | 200 | 115 | 85 | 68 | 360 | 4-14 |
DN32 | 200 | 140 | 100 | 78 | 370 | 4-18 |
DN40 | 200 | 150 | 110 | 88 | 370 | 4-18 |
DN50 | 200 | 165 | 125 | 102 | 385 | 4-18 |
DN65 | 250 | 185 | 145 | 122 | 400 | 4-18 |
DN80 | 250 | 200 | 160 | 138 | 415 | 8-18 |
DN100 | 250 | 220 | 180 | 158 | 435 | 8-18 |
DN125 | 250 | 250 | 210 | 188 | 465 | 8-18 |
DN150 | 300 | 285 | 240 | 212 | 497 | 8-18 |
DN200 | 350 | 340 | 295 | 268 | 550 | 12-12 |
DN250 | 450 | 405 | 355 | 320 | 610 | 12-12 |
DN300 | 500 | 460 | 410 | 375 | 660 | 12-12 |