Product Name - STAINLESS STEEL FLOAT AIR ELIMINATOR TRAP
MODEL NST22A
Product Category - · Steam and Flow Control Group · Traps · Float & Thermostatic Steam Traps
Product Brand - Nordsteam

Product Features
STAINLESS STEEL FLOAT AIR ELIMINATOR TRAP

INSTALLATION

The NST22A Series Free Floating Traps with  Air Vent will remove air and other gases from systems or piping systems without allowing the contained liquid to escape. The valve and seat, inside the NST22A, are connected to a stainless steel float. When there is no liquid in the body of the NST22A the float is at the bottom and  the valve is in open position, allowing air or other gases in the systems or piping system to escape. When liquids enter the NST22A, the float rises, forcing the valve plug into the valve seat, which closes the valve and prevents the liquids from escaping.

1.The NST22A should be properly sized and properly located in the system. The inlet piping should be the same size as the piping connection on the body, and a full port valve should be installed a head of the air eliminator.

2.Do not exceed the maximum allowable pressures and temperatures noted on the label of the NST22A body. Also, check to see if the air eliminator has the proper maximum differential pressure for your particular application.

3.The NST22A should be located at the highest point in the system or vessel where air can collect. The air eliminator must be installed, vertical, and with the inlet at the bottom. Make sure that the air eliminator is mounted in the proper direction, with the flow arrow on the body. This will allow the float mechanism to operate properly. Valves should be installed for ease of maintenance.

4. We recommend piping the discharge to a safe visible point or drain. 

5.Adhere to good piping practices by properly cleaning all piping before installing the NST22A. Clean the pipes by flushing to remove loose dirt. A strainer in the line leading to the air eliminator is recommended.

6.The inlet and outlet piping should be the same size as the NST22A’s connections. Do not reduce the size of the inlet on light loads; however, smaller pipe or tubing may be used on the outlet. Keep the piping as short as possible, with a minimum of valves and fittings.

7.Install gate valves or full ported ball valves (Do Not Use Globe Valves) so the NST22A can be isolated from the system to permit servicing.

MAINTENANCE

The NST22A Series is a maintenance free valve, composed of corrosion resistant components. No need for gaskets or adjustments .

SPARE PARTS
No Description Material
1 BODY AISI 304
2 CONNECTORS AISI 304
3 FLOAT AISI 304
4 VALVE SEAT CHROME STEEL
5 VALVE CHROME STEEL
6 FLOOT LEVER AISI 304
7 GUIDE PLATE AISI 304
8 BUCKET CLIP AISI 304

DIMENSIONS
Size L L1 H H1
3/4'' - 3/4'' 289 mm 155 mm 114 mm 28 mm

CONNECTION THREAD BSP
SIZES 3/4'' - 3/4''
WEIGHTS (KGS) 3,5

OPERATING CONDITIONS
MAX. ALLOWABLE PRESSURE PMA (BAR) 45
MAX. ALLOWABLE TEMPERATURE TMA (ºC) 350
MAX.OPERATING PRESSURE 30